Air Brake Storage Tank Leak Detection

Project Overview:

System must check three internal compartments and external welds for leakage. Leak rates of 1x10-² std. ml/sec. must be detected.

System Description:

Dual Channel system, the first channel consists of 8 microphones summed into one channel. The second channel consists of one .60" diameter microphone with 5/8" threaded fitting, alarm threshold set points, relay contact closure and white noise sensitivity validation.

Two stage testing: The internal compartment is checked first. A 0.60" microphone is screwed into a 5.8" threaded fitting of the center section. The two outside sections are pressurized to 300 psi. The internal .60" microphone is activated to detect leaks in the internal chambers. Stage two: All three compartments are pressurized to 300 psi. Eight microphones placed strategically around the external surface of the tank, are activated to detect for any leakage to atmosphere.

 
UE Systems Inc. Toll Free 1-800-223-1325 Phone 914-592-1220 Fax 914-347-2181  
email: info@uesystems.com